ini File Parameter Name
SS7_LINK_LAYER2_VARIANT
[Variant]
SS7_LINK_MTP2_ATTRIBUTES
[MTP2 Attributes Index]
SS7_CONGESTION_LOW_MARK
[Congestion Low Watermark]
SS7_CONGESTION_HIGH_MARK
[Congestion High Watermark]
SS7_LINK_M2UA_IF_ID
[Interface ID]
SS7_LINK_GROUP_ID
[Group ID]
SS7_LINK_TNL_MGC_LINK_NUMBE
R
SS7_LINK_TNL_ALIGNMENT_MODE Determines the MTP2 Tunneling: Alignment mode of signaling
SS7_LINK_TNL_CONGESTION_MOD
E
SS7_LINK_TNL_WAIT_START_COM
PLETE_TIMER
SS7_LINK_TNL_OOS_START_DELA
Y_TIMER
SS7_LINK_TNL_WAIT_OTHER_SIDE
_INSV_TIMER
SS7_LINKSET_SN_INDEX
[SN Number]
SS7_LINKSET_LINKSET_INDEX
[Link-set Number]
SS7_LINKSET_ROWSTATUS
V7122 Gateway User Guide
Description
Determines the variant (layer 2) of signaling link (TDM).
0 = NET_VARIANT_OTHER
1 = NET_VARIANT_ITU (default)
2 = NET_VARIANT_ANSI
3 = NET_VARIANT_CHINA
Determines the MTP2 attributes of signaling link (TDM).
The valid range is 0 to MAX_C7_MTP2_PARAMS_INDEX. The
default value is 3.
Determines the link congestion low mark of signaling link (TDM).
The valid range is 0 to 255. The default value is 5.
Determines the link congestion high mark of signaling link (TDM).
The valid range is 0 to 255. The default value is 20.
Determines the interface ID (M2UA) of signaling link.
The valid range is 0 to 0xFFFFFFFF. The default value is 0.
Determines the group ID (M3UA) of signaling link.
The valid range is 0 to 0xFFFF. The default value is 0.
Determines the MTP2 Tunneling: MGC link number (MTP2 \other
side\ of signaling link.
The valid range is 0 to 7. The default value is 0.
links in tunnel.
0 = M3B_ALIGNMENT_NORMAL
1 = M3B_ALIGNMENT_EMERGENCY (default)
Determines the MTP2 Tunneling: Congestion mode of signaling
links in tunnel.
0 = M3B_CONGESTION_ACCEPT (default)
1 = M3B_CONGESTION_DISCARD
Determines the MTP2 Tunneling Timer: wait start complete.
The valid range is 500 to 0xFFFFFFFF. The default value is
30000.
Determines the MTP2 Tunneling Timer: OOS start delay.
The valid range is 500 to 0xFFFFFFFF. The default value is 5000.
Determines the MTP2 Tunneling Timer: wait other side inservice.
The valid range is 500 to 0xFFFFFFFF. The default value is
30000.
Determines the first index field for line.
The valid range is 0 to 1. The default value is 0.
Determines the second index field for line.
The valid range is 0 to 7. The default value is 0.
Determines the RowStatusField for line.
The valid range is
acPARAMSET_ROWSTATUS_DOESNOTEXIST to
acPARAMSET_ROWSTATUS_DESTROY. The default value is
acPARAMSET_ROWSTATUS_DOESNOTEXIST.