ini File Field Name
Web Parameter Name
AddIEinSetup
[Add IE in SETUP]
SendIEonTG
[Trunk Groups to Send IE]
ISDNJapanNTTTimerT3J
A
EarlyAnswerTimeout
EnablePatternDetector
[Enable Pattern
Detector]
PDThreshold
PDPattern
212
Valid Range and Description
This parameter enables to add an optional Information Element data (in hex
format) to ISDN SETUP message.
For example: to add the following IE: '0x20,0x02,0x00,0xe1', define:
'AddIEinSetup = 200200e1'.
This IE is sent from the Trunk Group IDs defined by the
parameter 'SendIEonTG'.
A list of Trunk Group IDs (up to 50 characters) from where the optional ISDN
IE, defined by the parameter 'AddIEinSetup', is sent.
For example: 'SendIEonTG = 1,2,4,10,12,6'.
T3_JA timer (in seconds).
This parameter overrides the internal PSTN T301 timeout on the Users Side
(TE side).
If an outgoing call from the gateway to ISDN is not answered during this
timeout, the call is released.
The valid range is 10 to 240. The default value is 50.
Applicable only to Japan NTT PRI variant (ProtocolType = 16).
This timer is also affected by the parameter 'PSTNAlertTimeout'.
Defines the time (in seconds) the gateway waits for a CONNECT response
from the called party (Tel side) after sending a SETUP message. If the timer
expires, the call is answered by sending a 200 OK message (IP side).
The valid range is 0 to 600. The default value is 0 (disable).
Enables or disables activation of the Pattern Detector (PD).
Valid options include:
0 = Disable (default).
1 = Enable.
Defines the number of consecutive patterns to trigger the pattern detection
event.
The valid range is 0 to 31. The default is 5.
Defines the patterns that can be detected by the Pattern Detector.
The valid range is 0 to 0xFF.
V7122 GatewayUser Guide
Need help?
Do you have a question about the V7122 and is the answer not in the manual?