External Wait Cycles; Figure 4.17-15 Example Of External Wait Cycle Timing Chart - Fujitsu MB91F109 FR30 Hardware Manual

Fr30 series 32-bit microcontroller
Table of Contents

Advertisement

CHAPTER 4 BUS INTERFACE

4.17.7 External Wait Cycles

This section provides an external wait cycle timing chart.
External Wait Cycle Timing Chart
Bus width: 16 bits, access: half-words
CLK
A24-00
Read
D31-16
RDX
Write
D31-16
WR0X,1X
RDY
[Explanation of operation]
When implementing external wait cycles, set the RDYE bit of EPCR0 to "1" to validate the
input of the external RDY pin.
When using the external RDY signal, set at least 1 clock of automatic wait cycle; that is, set
"001" or more in the WTC bit of the AMD. The RDY signal is detected after, not during,
automatic wait cycles.
Enter the RDY signal synchronously with the falling edge of the CLK pin output. If the
external RDY is "L" at the falling edge of the CLK, a wait cycle is entered and the same BA1
cycle is repeated. If the external RDY is "H", the end of the wait cycle is assumed and the
BA2 cycle is entered.
172

Figure 4.17-15 Example of External Wait Cycle Timing Chart

BA1
#0
#0,1
BA1
BA1
BA1
wait
wait
wait
Automatic
Wait by RDY
wait
Bus cycle
BA1
BA2
#0:1
RDY