ExtremeWare XOS 11.5 supports only the Summit X450 family of switches and the BlackDiamond 8800 series switch.
configure pim register-checksum-to
configure pim register-checksum-to [include-data | exclude-data]
Description
Configures the checksum computation to either include data (for compatibility with Cisco Systems
products) or to exclude data (for RFC-compliant operation), in the register message.
Syntax Description
include-data
exclude-data
Default
Include data.
Usage Guidelines
None.
Example
The following command configures the checksum mode to include data for compatibility with Cisco
Systems products:
configure pim register-checksum-to include-data
History
This command was first available in ExtremeWare XOS 10.1.
Platform Availability
This command is available on all platforms.
ExtremeWare XOS 11.5 Command Reference Guide
Specifies to include data.
Specifies to exclude data.
configure pim register-checksum-to
1823