ExtremeWare XOS 11.5 supports only the Summit X450 family of switches and the BlackDiamond 8800 series switch.
Configuration and Image Commands
When naming or configuring an IP address for your network server, remember the requirements listed
above.
Local and Remote Filename Character Restrictions. This section provides information about the characters
supported by the switch for local and remote filenames.
When specifying a local or remote filename, the switch permits only the following characters:
Alphabetical letters, upper case and lower case (A-Z, a-z)
Numerals (0-9)
Period ( . )
Dash ( - )
Underscore ( _ )
Slash ( / ) Permitted only for remote files
When naming a local or remote file, remember the requirements listed above.
Messages Displayed by the Switch. When you download a new image, you see the following message:
Do you want to install image after downloading? (y - yes, n - no, <cr> - cancel)
Do one of the following:
Enter
if you want to install the image after download.
y
Enter
if you want to install the image at a later time.
n
Press [Enter] if you want to cancel the download.
Core Dump Messages. If you configure the switch to write core dump (debug) files to the internal
memory card and attempt to download a new software image, you might have insufficient space to
complete the image download. If this occurs, you must decide whether to continue the software
download or move or delete the core dump files from the internal memory. For example, if you have a
modular switch with an external memory card installed with space available, transfer the files to the
external memory card. On the Summit X450 family of switches, transfer the files from the internal
memory card to a TFTP server. This frees up space on the internal memory card while keeping the core
dump files.
The switch displays a message similar to the following and prompts you to take action:
Core dumps are present in internal-memory and must be removed before this download can
continue. (Please refer to documentation for the "configure debug core-dumps" command
for additional information)
Do you wnat to continue with download and remove existing core dumps? (y/n)
Enter
to remove the core dump files and download the new software image. Enter
y
action and transfer the files before downloading the image.
For information about configuring and sending core dump information, see the
and
core-dumps
Modular Switches Only. Specify
memory card installed in the external compact flash slot of the MSM. Use a PC with appropriate
hardware such as a compact flash reader/writer and follow the manufacturer's instructions to access
the compact flash card and place the image onto the card. For more information about installing the
1902
save debug tracefiles memorycard
memorycard
commands.
to download a an image from the external compact flash
ExtremeWare XOS 11.5 Command Reference Guide
to cancel this
n