Run Diagnostics - Extreme Networks ExtremeWare XOS Command Reference Manual

Software version 11.5
Hide thumbs Also See for ExtremeWare XOS:
Table of Contents

Advertisement

ExtremeWare XOS 11.5 supports only the Summit X450 family of switches and the BlackDiamond 8800 series switch.

run diagnostics

run diagnostics [extended | normal | stack-port] {slot [<slot> | A | B]}
Description
Runs normal or extended diagnostics on the switch, slot, or management module. On the Summit X450
family of switches, this command also runs diagnostics on the stacking ports.
Syntax Description
extended
normal
stack-port
slot
A | B
Default
N/A.
Usage Guidelines
Depending on your platform, use this command to run diagnostics on the switch, slot, management
module, or stack port.
Running Diagnostics—BlackDiamond 10808 Switch and BlackDiamond 8800 Series Switch Only. If you run
the diagnostic routine on an I/O module, that module is taken offline while the diagnostic test is
performed. The ports on the module do not forward traffic. Once the diagnostic test is completed, the
I/O module is automatically reset and becomes operational again.
After the switch runs the diagnostic routine, test results are saved in the module's EEPROM and
messages are logged to the syslog.
ExtremeWare XOS 11.5 Command Reference Guide
Runs an extended diagnostic routine. Takes the ports offline, and performs
extensive ASIC and packet loopback tests on all of the ports.
BlackDiamond 8800 series switch only—If you have a Power over Ethernet
(PoE) module installed, the switch also performs an extended PoE test, which
tests the functionality of the inline power adapter.
Runs a normal diagnostic routine. Takes the ports offline, and performs a
simple ASIC and packet loopback test on all of the ports.
Runs the diagnostic routine on the stack ports.
NOTE: This parameter is available only on the Summit X450 family of
switches.
Specifies the slot number of an I/O module.
NOTE: This parameter is available only on modular switches.
Specifies which MSM to run diagnostics on.
• A specifies the MSM installed in slot A.
• B specifies the MSM installed in slot B.
NOTE: This parameter is available only on modular switches.
run diagnostics