Extreme Networks ExtremeWare XOS Command Reference Manual page 1978

Software version 11.5
Hide thumbs Also See for ExtremeWare XOS:
Table of Contents

Advertisement

ExtremeWare XOS 11.5 supports only the Summit X450 family of switches and the BlackDiamond 8800 series switch.
Troubleshooting Commands
Output on the BlackDiamond 8800 Series Switch. The switch displays the following diagnostic
information:
If you have run diagnostics, a brief summary of the overall diagnostic test is displayed. Options are:
Diagnostics Pass—The diagnostic test has passed.
Diagnostics Fail—One or more diagnostic test has failed.
Diagnostics Interrupted—The diagnostic test was interrupted on the I/O module due to initiating an
MSM failover.
If you have never run diagnostics on a specific slot, the switch displays a message similar to the
following:
Diagnostics never ran on slot 6
If you attempt to view diagnostics information for a slot that does not have a module installed, the
switch displays a message similar to the following:
No card in slot 7
Output on the Summit X450 Family of Switches. The switch displays the following diagnostic information:
If you have run diagnostics, information includes the:
Date the test was run—The month, date, and year the test was run.
Test data—If the diagnostic test failed, the switch displays the name of the failed test. The switch
displays a message similar to the following:
MAC memory test failed
Summary—A brief summary of the overall diagnostic test. Options are:
Diagnostics Pass—The diagnostic test has passed.
Diagnostics Fail—One or more diagnostic tests have failed.
If you have never run diagnostics on the switch or stack ports, the switch displays a message similar to
the following:
Result: FAIL
Test date run is invalid. Please run Diagnostics.
Error reading diagnostics information.
This message is normal and expected if you have never run diagnostics on the switch. After you run
diagnostics, you should see information about the executed test.
Additional Guidelines Applicable to Modular Switches Only. If you use the
[<slot> | A | B]}
messages similar to the following:
Diagnostics never ran on slot 3
Or
Diagnostics never run
1978
command on a slot where diagnostics have not been run, the switch displays
show diagnostics {slot
ExtremeWare XOS 11.5 Command Reference Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Extremeware xos 11.5

Table of Contents