Setting Device Manager Preferences - Cisco AP775A - Nexus Converged Network Switch 5010 Configuration Manual

Fabric manager configuration guide, release 4.x
Hide thumbs Also See for AP775A - Nexus Converged Network Switch 5010:
Table of Contents

Advertisement

Setting Device Manager Preferences

S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Setting Device Manager Preferences
To set your preferences for the behavior of the Device Manager application, choose Device >
Preferences from the Device menu. You can set the following preferences:
Cisco MDS 9000 Family Fabric Manager Configuration Guide
6-8
Retry Requests x Time(s) After x sec Timeout—Allows you to set the retry request values. The
default settings are 1 time after a 5-second timeout.
Enable Status Polling Every x secs—Allows you to set the status polling value. The default setting
is enabled (checked) with a time of 40 seconds.
Trace SNMP Packets in Message Log—Allows you to set whether Device Manager traces SNMP
packets and logs the trace. The default setting is disabled (unchecked).
Register for Events After Open, Listen on Port 1163—Allows you to register this switch so that
events are logged once you open Device Manager. The default setting is enabled (checked).
Show WorldWideName (WWN) Vendor—Displays the worldwide name vendor name in any table
or listing displayed by Device Manager. If Prepend is checked, the name is displayed in front of the
IP address of the switch. If Replace is checked, the name is displayed instead of the IP address. The
default setting is enabled (checked) with the Prepend option.
Show Timestamps as Date/Time—Displays timestamps in the date/time format. If this preference
is not checked, timestamps are displayed as elapsed time. The default setting is enabled (checked).
Telnet Path—Sets the path for the telnet.exe file on your system. The default is telnet.exe, but you
need to browse for the correct location.
If you browse for a path or enter a path and you have a space in the pathname (for example,
Note
c:\program files\telnet.exe, then the path will not work. To get the path to work, manually
place quotes around it (for example, "c:\program files\telnet.exe").
Use Secure Shell Instead of Telnet—Specifies whether to use SSH or Telnet when using the CLI
to communicate with the switch. If enabled, you must specify the path to your SSH application. The
default setting is disabled.
CLI Session Timeout x secs (0= disable)—Specifies the timeout interval for a CLI session. Enter
0 to disable (no timeout value). The default setting is 30 seconds.
Show Tooltips in Physical View—Determines whether tooltips are displayed in Physical (Device)
View. The default setting is enabled (checked).
Label Physical View Ports With:—Specifies the type of label to assign to the ports when you are
in Physical (Device) View. The options are FICON and Interface. The default setting is Interface.
Export Table—Specifies the type of file that is created when you export a table using Device
Manager. The options are Tab-Delimited or XML. The default setting is Tab-Delimited.
Chapter 6
Device Manager
OL-17256-03, Cisco MDS NX-OS Release 4.x

Hide quick links: