Analog I/O Units
V OUT
Analog
I OUT
I/O
Unit
COM
Analog Inputs
510 k
510 k
510 k
510 k
Analog ground
Analog Input Terminals
IN
Analog input 0 +
Analog input 0 –
Analog input 1 +
Analog input 1 –
Analog ground
Analog
I/O Unit
Wiring for Analog Outputs
+
Analog device
with voltage
input
–
Note
1. Use shielded twisted-pair cables, but do not connect the shield.
2. When an input is not being used, short the + and – terminals.
3. Separate wiring from power lines (AC power supply lines, high-voltage
lines, etc.)
4. When there is noise in the power supply line, install a noise filter on the input
section and the Power Supply Unit.
CPM2C-MAD11 Internal Circuits
0+
Input 0
250
0–
1+
Input 1
250
1+
AG
CPM2C-MAD11 Terminal Arrangements
0 +
0 –
1 +
1 –
AG
Analog Input Wiring
Analog Output Wiring
Analog
V+
+
input device
with voltage
input
–
–
V OUT
Analog
I OUT
I/O
Unit
COM
Analog Outputs
Analog ground
Analog Output Terminals
Analog voltage output
V+
Output common
–
Analog current output
I+
Not used
NC
Not used
NC
Analog
+
+
output
device
–
–
I+
Analog
I/O Unit
–
Section
+
Analog device
with current
input
–
V+
–
Output
I+
NC
NC
OUT
Analog
I/O Unit
Analog
+
input device
with current
input
–