CPM2A/CPM2C Pulse Output Functions
2-5-1 Using Single-phase Pulse Outputs Without Acceleration and
Deceleration (Fixed Duty Ratio)
Select the pulse output number.
Wire the outputs.
PC Setup (DM 6629)
Create a ladder diagram program.
Single-phase Pulse Outputs
SET
PULS(65)
PULSES
instruction
Specify relative or
absolute pulses.
Pulse output SV
(8 digits BCD)
MODE
INI(61)
CONTROL
instruction
Stop pulse outputs.
Change pulse output PV.
DM 6629,
bits 04 to 07
Selecting the Pulse
Output Number
Pulse output number 0 or 1
Output numbers: 01000 and 01001
PV coordinate system for pulse output numbers 0 and 1
PULS(65): For setting the number of output pulses.
SPED(64): For pulse output control without acceleration and deceleration.
INI(61): For stopping pulse outputs and changing the pulse output PV.
PRV(62): For reading the pulse output PV and status.
SPED(64)
SPEED
OUTPUT
instruction
Output mode: Continuous or
Independent
Target frequency: 10 Hz to 10 kHz
Start pulse outputs.
Every scan
Pulse output status
AR 11
AR 12
PC Setup
Select either pulse number 0 or 1.
Output number
01000
01001
Every scan
Immediately
Pulse output PV
PRV(62)
SR 228
SR 229
SR 230
SR 231
0
1
Section
Pulse output 0
Pulse output 1
HIGH-SPEED COUNTER
PV READ instruction
Read pulse output PV.
Read pulse output
status.
Pulse output number