Omron CPM1 - PROGRAMING MANUAL 02-2001 Programming Manual page 158

Hide thumbs Also See for CPM1 - PROGRAMING MANUAL 02-2001:
Table of Contents

Advertisement

Synchronized Pulse Control (CPM2A/CPM2C Only)
Selecting the Input Mode
Selecting the Pulse
Synchronization Input
Frequency
Select the differential phase input mode, the pulse + direction input mode, the
up/down pulse input mode, or the increment mode. These modes are explained
below.
Select one of the following as the input frequency range: 10 Hz to 500 Hz, 20 Hz
to 1 kHz, or 300 Hz to 20 kHz. For more information on input frequencies, refer to
the following diagrams.
Differential Phase Input Mode
In the differential phase input mode, the count is incremented or decremented
according to two differential phase signals (phase A and phase B) with a multi-
plication factor of 4.
ON
Phase A
OFF
ON
Phase B
OFF
Pulse + Direction Input Mode
In the pulse + direction input mode, pulse signals and direction signals are input,
and the count is incremented or decremented according to the direction signal
status.
ON
Pulse inputs
OFF
ON
Direction
inputs
OFF
Up/Down Pulse Input Mode
In the up/down pulse input mode, CW signals (up pulses) and CCW signals
(down pulses) are input, and the count is incremented or decremented accord-
ingly.
ON
CW inputs
OFF
ON
CWW inputs
OFF
1,000
Nms
Frequency =
N
1,000
Nms
Frequency =
Incremented
1,000
Nms
Frequency =
N
Section
2-7
N
Decremented
137