When the FW-BLK/RV-BLK input action is set to "Deceleration stop"
(when the motor does not stop while the FW-BLK input is ON)
1. When the FW-BLK input is turned ON during operation in the forward direction, the motor starts the stopping
movement.
2. Even after the FW-BLK input is turned OFF, the motor continues the deceleration operation until it stops.
When the operation is stopped, the READY output is turned ON.
FW-BLK input
READY output
Internal speed command
Excitation
Motor excitation
Non-excitation
Electromagnetic brake
Release
When the FW-BLK/RV-BLK input action is set to "Immediate stop"
1. If the FW-BLK input is turned ON during operation in the forward direction, the motor will stop.
2. The motor stops at the command position at the time when the ON status of the FW-BLK input was detected.
FW-BLK input
READY output
Internal speed command
Excitation
Motor excitation
Non-excitation
Electromagnetic brake
Release
* It varies depending on the driving condition.
2 ms or more
ON
OFF
ON
OFF
2 ms or less
Hold
2 ms or more
ON
OFF
2 ms or less
ON
OFF
*
Hold
2 ms or less
Input signals