Orientalmotor AZX Series Operating Manual page 190

Hide thumbs Also See for AZX Series:
Table of Contents

Advertisement

Objects of manufacturer-specific area
z DIN composite input function (4880h to 4885h)
Selects an input signal to be assigned to DIN as the composite input function.
Index
Sub
DIN0 composite
4880h
00h
input function
DIN1 composite
4881h
00h
input function
DIN2 composite
4882h
00h
input function
DIN3 composite
4883h
00h
input function
DIN4 composite
4884h
00h
input function
DIN5 composite
4885h
00h
input function
z DOUT0 composite output function (4890h to 4895h)
Selects an output signal for logical operation with the signal of DOUT.
Index
Sub
DOUT0 composite
4890h
00h
output function
DOUT1 composite
4891h
00h
output function
DOUT2 composite
4892h
00h
output function
DOUT3 composite
4893h
00h
output function
DOUT4 composite
4894h
00h
output function
DOUT5 composite
4895h
00h
output function
z DOUT composite inverting mode (48A0h to 48A5h)
Changes the ON-OFF setting of the composite output function of DOUT.
Index
Sub
DOUT0 composite
48A0h
00h
inverting mode
DOUT1 composite
48A1h
00h
inverting mode
DOUT2 composite
48A2h
00h
inverting mode
DOUT3 composite
48A3h
00h
inverting mode
DOUT4 composite
48A4h
00h
inverting mode
DOUT5 composite
48A5h
00h
inverting mode
190
Name
Type
Access
U8
RW
U8
RW
U8
RW
U8
RW
U8
RW
U8
RW
Name
Type
Access
U8
RW
U8
RW
U8
RW
U8
RW
U8
RW
U8
RW
Name
Type
Access
U8
RW
U8
RW
U8
RW
U8
RW
U8
RW
U8
RW
PDO
Save
Initial value
No
0
No
0
No
0
No
0
No
0
No
0
PDO
Save
Initial value
No
128
No
128
No
128
No
128
No
128
No
128
PDO
Save
Initial value
No
0
No
0
No
0
No
0
No
0
No
0
Range
Update
C
C
C
Input signals list
_
p.129
C
C
C
Range
Update
C
C
C
Output signals list
_
p.130
C
C
C
Range
Update
C
C
C
0: Non invert
1: Invert
C
C
C

Advertisement

Table of Contents
loading

Table of Contents