Orientalmotor AZX Series Operating Manual page 164

Hide thumbs Also See for AZX Series:
Table of Contents

Advertisement

Objects of profile area
z Supported homing methods (60E3h)
This indicates the Homing (return-to-home) method supported by the driver.
Index
Sub
00h
Number of entries
01h
1st supported homing method
02h
2nd supported homing method
03h
3rd supported homing method
60E3h
04h
4th supported homing method
05h
5th supported homing method
06h
6th supported homing method
07h
7th supported homing method
Details of range
Setting value
−1
Return-to-home operation of Oriental Motor's specifications
17
Return-to-home with the limit sensor (FW-LS/RV-LS), to start running in the negative direction.
18
Return-to-home with the limit sensor (FW-LS/RV-LS), to start running in the positive direction.
24
Return-to-home with the home sensor (HOMES), to start running in the positive direction.
28
Return-to-home with the home sensor (HOMES), to start in the negative direction.
35, 37*
Home preset
* 35 and 37 perform the same action.
z Following error actual value (60F4h)
This indicates the deviation between the command position and the position actual value (feedback position). (step)
Index
Sub
Type
60F4h
00h
INT32
z Digital inputs (60FDh)
This indicates the status of direct I/O.
Index
Sub
Type
60FDh
00h
U32
Details of range
Bit
Name
0
RV-BLK*1
1
FW-BLK*1
2
HOMES*1
3 to 15
16
EXT1*1
17
EXT2*1
18, 19
20
ZSG
21 to 23
24
DIN0
25
DIN1
26
DIN2
27
DIN3
28
DIN4
29
DIN5
30, 31
*1 To acquire the status, input signals are required to assign to the input terminals IN0 and IN5 of the I/O signal
connector (CN7). Assign using the DIN0 input function (4840h) to the DIN5 input function (4845h).
164
Name
Type
Access
PDO
Save
RO
TxPDO
Access
PDO
Save
RO
TxPDO
Status of RV-BLK input (0: OFF, 1: ON)*2
Status of FW-BLK input (0: OFF, 1: ON)*2
Status of HOMES input (0: OFF, 1: ON)*2
Reserved
Status of EXT1 input (0: OFF, 1: ON)*2
Status of EXT2 input (0: OFF, 1: ON)*2
Reserved
Status of ZSG output (0: OFF, 1: ON)*2
Reserved
Status of DIN0 input (0: Not carrying current, 1: Carrying current)*3
Status of DIN1 input (0: Not carrying current, 1: Carrying current)*3
Status of DIN2 input (0: Not carrying current, 1: Carrying current)*3
Status of DIN3 input (0: Not carrying current, 1: Carrying current)*3
Status of DIN4 input (0: Not carrying current, 1: Carrying current)*3
Status of DIN5 input (0: Not carrying current, 1: Carrying current)*3
Reserved
Access
PDO
Save
U8
RO
No
INT8
RO
No
INT8
RO
No
INT8
RO
No
INT8
RO
No
INT8
RO
No
INT8
RO
No
INT8
RO
No
Description
Initial value
Range
Update
0
Initial value
Range
Update
Description
Initial value
Range
Update
7
17
18
24
28
35
37
−1