Input signals
When the FW-BLK/RV-BLK input action is set to "Deceleration stop"
(when the motor stops while the FW-BLK input is ON)
1. When the FW-BLK input is turned ON during operation in the forward direction, the motor starts the stopping
movement.
2. When the operation is stopped, the READY output is turned ON.
3. If an operation start signal in the reverse direction is input while the FW-BLK input is ON, the READY output is
turned OFF to start operation.
FW-BLK input
READY output
MOVE output
Internal speed command
Motor excitation
Electromagnetic brake
FW-BLK input
READY output
MOVE output
Internal speed command
Motor excitation
Electromagnetic brake
48
ON
1
OFF
ON
OFF
ON
OFF
Excitation
Non-excitation
Hold
Release
2 ms or more
ON
OFF
ON
OFF
ON
OFF
2 ms or less
Excitation
Non-excitation
Hold
Release
2
3
2 ms or less
2 ms or less