Objects of CoE communication area
Details of Sync Manager 2 Synchronization objects
Sub
01h
Synchronization Type
02h
Cycle Time [ns]
03h
Shift Time [ns]
04h
Synchronization Types supported
05h
Minimum Cycle Time [ns]
06h
Calc and Copy Time [ns]
09h
Delay Time [ns]
20h
Sync Error
z Sync Manager 3 Synchronization (1C33h)
This is used to set the Synchronization Type of the Sync Manager 3 (SM3) and indicates the status.
Index
Sub
00h
01h
02h
03h
04h
05h
1C33h
06h
07h
08h
09h
0Ah to 1Fh Reserved
20h
Details of Sync Manager 3 Synchronization objects
Sub
01h
Synchronization Type
02h
Cycle Time [ns]
03h
Shift Time [ns]
04h
Synchronization Types supported
05h
Minimum Cycle Time [ns]
06h
Calc and Copy Time [ns]
09h
Delay Time [ns]
20h
Sync Error
152
Name
00h: Free Run mode (asynchronous)
01h: Sync Manager 2 event synchronization mode
02h: DC mode (SYNC0 event synchronization)
Indicates the Cycle Time of the SYNC0 event.
The Shift Time is not supported. The read value is always 0.
Indicates the Synchronization Type supported.
Bit0: Free Run mode (asynchronous)
Bit1: Sync Manager 2 event synchronization mode
Bit2: DC mode (SYNC0 event synchronization)
Indicates the Minimum Cycle Time supported.
Indicates the minimum value of the internal calculation and copy time that
is needed from the Sync Manager 2 event to the SYNC0 event.
The Delay Time is not supported. The read value is always 0.
Changes to 1 if the Sync Error is detected.
Name
Type
Number of entries
U8
Synchronization Type
U16
Cycle Time [ns]
U32
Shift Time [ns]
U32
Synchronization Types
U16
supported
Minimum Cycle Time [ns]
U32
Calc and Copy Time [ns]
U32
Reserved
U32
Reserved
U16
Delay time [ns]
U32
U16
Sync Error
BOOL
Name
00h: Free Run mode (asynchronous)
02h: DC mode (SYNC0 event synchronization)
22h: Sync Manager 2 event synchronization mode
Indicates the Cycle Time of the SYNC0 event.
The Shift Time is not supported. The read value is always 0.
Indicates the Synchronization Type supported.
Bit0: Free Run mode (asynchronous)
Bit1: Sync Manager 2 event synchronization mode
Bit2: DC mode (SYNC0 event synchronization)
Indicates the Minimum Cycle Time supported.
Indicates the minimum value of the internal calculation and copy time that
is needed from the SYNC0 event to the Sync manager 3 event.
The Delay Time is not supported. The read value is always 0.
Changes to 1 if the Sync Error is detected.
Description
Access
PDO
Save
Initial value
RO
No
20h
RW
No
02h
RO
No
RO
No
RO
No
0007h
0003 D090h
RO
No
(250,000 ns)
0002 49F0h
RO
No
(150,000 ns)
RO
No
RO
No
Description
Range
Update
00h, 02h, 22h
A
0
0
0