Orientalmotor AZX Series Operating Manual page 195

Hide thumbs Also See for AZX Series:
Table of Contents

Advertisement

z User output (USR-OUT) source B function (4964h, 4965h)
Sets the output source B of USR-OUT.
Index
Sub
User output (USR-OUT0)
4964h
00h
source B function
User output (USR-OUT1)
4965h
00h
source B function
z User output (USR-OUT) source B inverting mode (4966h, 4967h)
Changes the ON/OFF setting of the output source B of USR-OUT.
Index
Sub
User output (USR-OUT0)
4966h
00h
source B inverting mode
User output (USR-OUT1)
4967h
00h
source B inverting mode
z User output (USR-OUT) logical operation (4968h, 4969h)
Sets the logical combination of the user output sources A and B of USR-OUT.
Index
Sub
User output (USR-OUT0)
4968h
00h
logical operation
User output (USR-OUT1)
4969h
00h
logical operation
z Extended input (EXT-IN) function (4970h)
Selects an input signal to be assigned to the HOME PRESET switch.
Index
Sub
Type
Access
4970h
00h
U8
RW
z Extended input (EXT-IN) inverting mode (4971h)
Changes the ON-OFF setting of the input signal to be assigned to the HOME PRESET switch.
Index
Sub
Type
Access
4971h
00h
U8
RW
z Extended input (EXT-IN) interlock releasing time (4972h)
Normally, the HOME PRESET switch is interlocked. Pressing and holding the switch for a certain amount of time will
release the interlock and enable the assigned function. This parameter is used to set the amount of time that the
switch must be pressed and held down in order to release the interlock.
Index
Sub
Type
Access
4972h
00h
INT8
RW
z Extended input (EXT-IN) interlock releasing duration (4973h)
Sets the amount of time that the state of releasing the interlock is maintained.
Index
Sub
Type
Access
4973h
00h
INT8
RW
z Extended input (EXT-IN) ON monitor time (4974h)
When a signal assigned to the switch is input, the LED is lit. This parameter is used to set the amount of time that the
LED is lit.
Index
Sub
Type
Access
4974h
00h
INT8
RW
Name
Type
Access
U8
RW
U8
RW
Name
Type
Access
U8
RW
U8
RW
Name
Type
Access
U8
RW
U8
RW
PDO
Save
Initial value
No
9
PDO
Save
Initial value
No
0
PDO
Save
Initial value
No
10
PDO
Save
Initial value
No
30
PDO
Save
Initial value
No
10
Objects of manufacturer-specific area
PDO
Save
Initial value
No
128
No
128
PDO
Save
Initial value
No
0
No
0
PDO
Save
Initial value
No
1
No
1
Range
_
Input signals list
p.129
Range
Update
0: Non invert
C
1: Invert
Range
Update
0: Disable
A
1 to 50 (1=0.1 s)
Range
Update
0 to 50 (1=0.1 s)
A
Range
Update
0 to 50 (1=0.1 s)
A
Range
Update
C
Output signals list
_
p.130
C
Range
Update
C
0: Non invert
1: Invert
C
Range
Update
C
0: AND
1: OR
C
Update
C
195