Orientalmotor AZX Series Operating Manual page 47

Hide thumbs Also See for AZX Series:
Table of Contents

Advertisement

When the STOP input action is set to "Immediate stop"
1. If the STOP input is turned ON during operation, the motor stops at the command position at the time the ON
state of the STOP input is detected.
2. When the STOP input is turned OFF, the READY output is turned ON.
STOP input
READY output
MOVE output
Internal speed command
Motor excitation
Non-excitation
Electromagnetic brake
* It varies depending on the driving condition.
z FW-BLK input, RV-BLK input
Turning the FW-BLK input or the RV-BLK input ON will stop the operation according to the setting of the "FW-BLK/
RV-BLK input action" parameter. Turning the FW-BLK input ON will stop the operation in the forward direction, and
turning the RV-BLK input ON will stop the operation in the reverse direction. When the operation is stopped, the
remaining travel amount is cleared. While an input that has stopped the operation is ON, the motor will not operate
even if an operation start signal to operate in the same direction as the stop signal is input. An operation start signal
in the opposite direction can be used for operation.
Related parameter
MEXE02
code
p5
FW-BLK/RV-BLK input action
The following information is generated when the FW-BLK input or the RV-BLK input is turned ON.
 When the FW-BLK input is turned ON: Forward operation prohibition
 When the RV-BLK input is turned ON: Reverse operation prohibition
2 ms or more
ON
OFF
ON
OFF
2 ms or less
ON
OFF
*
Excitation
Hold
Release
Name
Sets how to stop the motor
when the FW-BLK input or the
RV-BLK input is turned ON.
2 ms or less
Description
Setting range
0: Immediate stop
1: Deceleration stop
Input signals
Initial value
0