Orientalmotor AZX Series Operating Manual page 27

Hide thumbs Also See for AZX Series:
Table of Contents

Advertisement

„ User output
User output (USR-OUT) is a method in which a signal is output by using the internal I/O.
Assign two types of signals (A and B) to a single user output. USR-OUT is output when the logical combination of A
and B is established.
No wiring is required and this function can be used together with direct I/O. Up to two user outputs can be set.
Name
User output source A function
User output source A inverting mode
User output source B function
User output source B inverting mode
User output logical operation
Setting example: When the IN-POS output and the READY output are turned ON, USR-OUT is output.
If the parameters are set as shown in the table, the status where positioning operation is completed and operation is
ready to start can be checked by a single output signal (USR-OUT0).
MEXE02 code
User output (USR-OUT0) source A function
User output (USR-OUT0) source A inverting mode
p9
User output (USR-OUT0) source B function
User output (USR-OUT0) source B inverting mode
User output (USR-OUT0) logical operation
Selects the output function A.
Changes the ON-OFF setting of the output function A.
Selects the output function B.
Changes the ON-OFF setting of the output function B.
Sets the logical combination [AND (logical product) or OR (logical sum)]
of the output function sources A and B.
Name
Overview of I/O signals
Description
Setting value
IN-POS
Non invert
READY
Non invert
AND
27