Settings related to cascade connection

The second processor (2nd UNIT) is cascade connected to the first processor,
enabling the number of input channels to be greatly increased. To control the second
processor from the console, press [2nd UNIT] on the panel to turn it on.
Settings related to cascade connection can be made on the following screen.
Settings related to cascade connection
1. While holding down [SHIFT], press [PROJECT].
2. Press CURSOR [UP], then [F1] (SYSTEM CONFIG).
3. Press [PAGE DOWN].
fig.x-x3
1
... VM link audio through
With two consoles ring connected, the signals of console-in and talkback are stopped
at the first device and do not reach the next one. This switch is used for passing the
sound signal to the next connected device. With ring connection, set this switch to
"THRU" when necessary. Place the cursor, select with the V1 knob and enter with
[F1].
2
,
3
... Cascade switch/attenuator
This switch is used for uni-directional flow (2nd UNIT to 1st UNIT) for each cascade
connected bus. Switch
3
for setting the 1 to 12 Flex Buses. Place the cursor and turn the switch on or off
with [F1] to [F6]. The V1 to V6 knobs are for setting the attenuator level of each bus.
If sound deterioration occurs on the 1st UNIT bus as a result of cascade connection,
these knobs can be used to suppress the sound level.
4
... Cascade delay correct
In the case of cascade connection, the 2nd UNIT signal delays for some sample time
from the 1st UNIT signal. Turning this switch on corrects it by also delaying the 1st
UNIT signal for the same amount of time. Place the cursor and turn the switch on or
Chapter 2 Basic Operations and Their Settings (System/Project)
2
is used for setting the cue and main buses, and switch
For cascade connection, a
VM-24C (sold separately)
needs to be installed on the
processor. For installation,
see the manual for the
processor (VM-7200/7100).
When the VM link is ring
connected, a second
processor cannot be added.
The same switch for the
second console must not
be set to "THRU" if this
one is already. Otherwise,
a signal loop occurs
resulting in abnormal
sounds.