Moving (Move) - Roland VM-C7100 Owner's Manual

V-mixing console
Hide thumbs Also See for VM-C7100:
Table of Contents

Advertisement

Chapter 11 Recording/Playing Back Fader or Knob Actions (Automix)

Moving (MOVE)

This function is used to move data in a specified region to another time position or
another channel.
fig.11-05_70
IN/OUT
These fields display the region of data to be moved. The value of REGION SET (p.
211) indicates the region to be moved.
FROM
This field sets the reference position in data to be moved. The position specified here
is moved to the position specified in the TO field.
TO
This field sets up the position to which data is to be moved.
DESTINATION
This field sets up the channel to which the data is to be moved. The destination
channel will be marked with the letter "D."
INSERT ON
This field specifies the moving method. To move by overwriting, set it to "OFF." To
move by insertion, set it to "ON." In this case, data following the point specified with
TO will be placed after the inserted data.
1. Check if the AUTO MIX VIEW screen is displayed (p. 208).
2. Press CURSOR [DOWN] to move the cursor over to the VIEW/SOURCE/
VALUE TRIM section.
3. Press [F6] (EDITMENU).
The EDIT MENU dialog is displayed. To clear the displayed dialog, press [F6]
(EXIT).
4. Press CURSOR [UP] to move the cursor to the top section in the dialog.
5. Press [F2] (MOVE) to display the MOVE screen.
6. Press CURSOR [DOWN] to move the cursor to the bottom section on the
screen.
7. Check IN/OUT to confirm the region of the data to be moved.
To reset the region, reset REGION SET (p. 211).
214
Only one value can be set
for DESTINATION. To
move data in more than
one channels at a time,
specify the destination
channel with the smallest
number. Since the
destination channels are
assigned for moving, they
correspond to the channels
storing the data to be
moved. For example, if the
channels storing the data to
be moved are Channels 1,
2, 5 and 6, setting
DESTINATION at "7"
causes the data to be
moved to Channels 7, 8, 11
and 12. You cannot set
DESTINATION to any
channels that do not
correspond to the channels
storing the data to be
moved. For example, you
cannot specify Channels 21
to 24 as the destination
channels if the channels
storing data to be moved
are Channels 20 and 24.
Specify the region subject
to editing before
attempting to display the
screen for the move
operation. Without the
region subject to editing set
up, the screen for the move
operation cannot be
displayed.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vm-c7200