Mitsubishi Electric M80V Series Manual page 561

Hide thumbs Also See for M80V Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Interface Manual
4 Explanation of Interface Signals
4.4 PLC Output Signals (Data Type: R***)
Cont.
Signal name
G/B spindle synchronization: Position error compensation
A
scale, and the number of times of compensations
[Function]
Set the magnification for the position error compensation amount obtained the first time and the number of times to update
the compensation amount after the "G/B spindle synchronization: Position error compensation" signal (GBCMON) is
turned ON.
[Operation]
F
8 7
(1)
R390
(1) Magnification for the first compensation amount
(2) The number of times of compensations
 In "Magnification for the first compensation amount", set the magnification for the position error compensation amount
obtained the first time after the "G/B spindle synchronization: Position error compensation" signal (GBCMON) is turned
ON. (Setting increment: 1/10 times)
When "0" is set, it will be treated as "1".
 In "The number of times of compensations", set the number of times to update the compensation amount after the "G/B
spindle synchronization: Position error compensation" signal (GBCMON) is turned ON.
When "0" is set, compensation is repeated by 16 times.
IB-1501616-D
0
(2)
548
Abbrev.
Common ($)
R390

Advertisement

Table of Contents
loading

This manual is also suitable for:

M800v series

Table of Contents