Interface For Consecutive Writes Detection Log - Mitsubishi Electric M80V Series Manual

Hide thumbs Also See for M80V Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Interface Manual
5 Appx.1: PLC window
5.2 PLC Window Interface

5.2.6 Interface for Consecutive Writes Detection Log

 Detection log area (Area where NC sets data)
R register
R20058
Number of consecutive writes detected
R20059
Consecutive write window No.
IB-1501616-D
Item
The NC detects that consecutive write of parameters was performed
through the write window.
The number of detections is stored in R20058.
This number is counted up only at the first detection after the NC power is
turned ON. This number is retained even after the power is turned OFF.
The NC detects that consecutive write of parameters was performed
through the write window.
The head register number of write window at the detection is stored in
R20059.
Regardless of the number of consecutive write operations, the head R reg-
ister number of the first detected window after turning ON the power.
Details
708