Mitsubishi Electric M80V Series Manual page 631

Hide thumbs Also See for M80V Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Interface Manual
4 Explanation of Interface Signals
4.4 PLC Output Signals (Data Type: R***)
Cont.
Signal name
MES interface library:
A
Subprogram number at alarm
[Function]
The subprogram number at the alarm occurrence is stored here.
[Operation]
When an alarm occurs, the ASCII code (hexadecimal number) corresponding to the subprogram at that time is specified
automatically.
"0" is specified while subprogram is not in execution.
When MES interface library function is invalid, this signal is set to "0".
Cont.
Signal name
MES interface library:
A
N number at alarm
[Function]
The sequence number at the alarm occurrence is stored here.
[Operation]
When an alarm occurs, the sequence number at that time is automatically set.
When MES interface library function is invalid, this signal is set to "0".
Cont.
Signal name
MES interface library:
A
B number at alarm
[Function]
The block number at the alarm occurrence is stored here.
[Operation]
When an alarm occurs, the block number at that time is automatically set.
When MES interface library function is invalid, this signal is set to "0".
Cont.
Signal name
MES interface library:
A
G code modal status
[Function]
The G code at the alarm occurrence is stored here.
[Operation]
When an alarm occurs, the G code corresponding to the G code modal is set in ASCII code.
The modal status of G code is set according to R register "G code modal registration selection" (R14604,5).
When MES interface library function is invalid, this signal is set to "0".
[Related signals]
(1) MES interface library: G code modal registration selection (R14604,5)
Cont.
Signal name
MES interface library:
A
Spindle 1 load
[Function]
The current of the 1st spindle at the alarm occurrence is stored here.
[Operation]
When an alarm occurs, the current of the 1st spindle is automatically set.
The maximum current is set by 1% increments regardless of the value of "#1256 set28/bit2" (Change current FB (load)
output unit).
When MES interface library function is invalid, this signal is set to "0".
IB-1501616-D
Abbrev.
$1
$2
R14882
R15132
R15382
to
to
R14897
R15147
R15397
Abbrev.
$1
$2
R14898,
R15148,
R15398,
9
9
Abbrev.
$1
$2
R14900,
R15150,
R15400,
1
1
Abbrev.
$1
$2
R14902
R15152
R15402
to
to
R14933
R15183
R15433
Abbrev.
$1
$2
R14934 R15184 R15434 R15684 R15934 R16184 R16434 R16684
618
$3
$4
$5
$6
R15632
R15882
R16132
to
to
to
to
R15647
R15897
R16147
$3
$4
$5
$6
R15648,
R15898,
R16148,
9
9
9
9
$3
$4
$5
$6
R15650,
R15900,
R16150,
1
1
1
1
$3
$4
$5
$6
R15652
R15902
R16152
to
to
to
to
R15683
R15933
R16183
$3
$4
$5
$6
$7
$8
R16382
R16632
to
to
R16397
R16647
$7
$8
R16398,
R16648,
9
9
$7
$8
R16400,
R16650,
1
1
$7
$8
R16402
R16652
to
to
R16433
R16683
$7
$8