4 Explanation of Interface Signals
4.1 PLC Input Signals (Bit Type: X***)
Cont.
Signal name
Reflection of reserved tool wear com-
A
pensation is complete
[Function]
This signal notifies the PLC that the contents of the reserved tool wear compensation memory have been reflected to the
tool wear compensation memory.
[Operation]
Refer to the page of the "Request for reflecting reserved tool wear compensation" signal (TWIN: YD0F).
When the "Request for reflecting reserved tool wear compensation" signal (TWIN) turns OFF, this signal also turns OFF.
[Related signals]
(1) Reservation of tool wear compensation (TWR: Y1CB8)
(2) Request for reflecting reserved tool wear compensation (TWIN: YD0F)
(3) Reserved tool wear compensation not reflected (TWNIN: XD0E)
Cont.
Signal name
3D coordinate conversion: Manual feed
A
valid
[Function]
While this signal is ON, the coordinate system for manual operation is selected by the "3D coordinate conversion: Manual
feed coordinates switch" signal (YD14).
While this signal is OFF, manual feed is carried out with respect to the machine coordinate system.
[Operation]
This signal turns ON when the following conditions are all satisfied:
 Jog, incremental or handle mode is being selected.
 G68 (M system)/G68.1 (L system) (3D coordinate conversion) has been commanded at least once.
However, if the command is canceled by G69 (M system)/G69.1 (L system) (3D coordinate conversion cancel), the sig-
nal will not turn ON until G68/G68.1 is commanded again.
[Related signals]
(1) 3D coordinate conversion: Manual feed coordinates conversion (YD14)
Cont.
Signal name
Rotation center error compensation in
A
progress
[Function]
This signal indicates that the rotation center error compensation is valid.
[Operation]
This signal turns "1" when the additional specification of rotation center error compensation is enabled and the "Rotation
center error compensation enabled" signal (RCEE) is "1".
This signal turns "0" when the rotation center error compensation is disabled.
[Related signals]
(1) Rotation center error compensation enabled (RCEE: YD15)
IB-1501616-D
Abbrev.
$1
$2
TWOUT
XD0F
XE4F
XF8F
Abbrev.
$1
$2
XD14
XE54
XF94
Abbrev.
$1
$2
RCEI
XD15
XE55
XF95
240
$3
$4
$5
$6
X10CF
X120F
X134F
$3
$4
$5
$6
X10D4
X1214
X1354
$3
$4
$5
$6
X10D5
X1215
X1355
$7
$8
X148F
X15CF
$7
$8
X1494
X15D4
$7
$8
X1495
X15D5

Advertisement