Mitsubishi Electric M80V Series Manual page 206

Hide thumbs Also See for M80V Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Interface Manual
4 Explanation of Interface Signals
4.1 PLC Input Signals (Bit Type: X***)
Cont.
Signal name
A
In automatic initial set mode
[Function]
This signal indicates that automatic initial set mode is selected.
[Operation]
After the "All axes smoothing zero" (command acceleration/deceleration delay is zero) is verified, the mode changes from
other mode to the automatic initial set mode.
Mode input
All axes smoothing zero
(TSMZ)
In automatic initial set mode
(ASTO)
[Related signals]
(1) All axes smoothing zero (TSMZ: XC1A)
Cont.
Signal name
A
In JOG-handle simultaneous mode
[Function]
This signal indicates that the simultaneous operation of JOG and handle mode has been entered.
[Operation]
This signal turns ON regardless of the "All axes smoothing zero" signal (TSMZ) which informs there is no delay caused by
the acceleration/deceleration time constants.
This signal will not turn ON when the "Jog mode" signal (J) is OFF, even if the "Jog handle synchronous" signal (JHAN) is
ON.
[Timing chart]
Jog mode (J)
Feed axis selection (+J1 to +J8,-J1 to -J8)
All axes smoothing zero (TSMZ)
Jog handle synchronous (JHAN)
In Jog-handle simultaneous mode (JHANO)
[Related signals]
(1) Jog mode (J: YC00)
(2) Jog handle synchronous (JHAN: YC7B)
(3) All axes smoothing zero (TSMZ: XC1A)
Abbrev.
$1
ASTO
XC05
Automatic initial set mode
Other mode
Abbrev.
$1
JHANO
XC06
193
$2
$3
$4
$5
XD45
XE85
XFC5
X1105
$2
$3
$4
$5
XD46
XE86
XFC6
X1106
$6
$7
$8
X1245
X1385
X14C5
Other mode
$6
$7
$8
X1246
X1386
X14C6
IB-1501616-D