4 Explanation of Interface Signals
4.3 PLC Output Signals (Bit Type: Y***)
Cont.
Signal name
Power consumption computation: Enable consumption ac-
A
cumulation 1 to 4
[Function]
This signal enables "Consumption accumulation 1 to 4".
[Operation]
The following kinds of consumption accumulation are performed while this signal is ON.
 Accumulated consumption of entire drive system 1 to 4 (R122 to 9)
 Accumulated consumption of devices other than drive system 1 to 4 (R130 to 7)
 Total accumulated consumption 1 to 4
 Drive system's fixed consumption correction 1 to 4
 Accumulated consumption of servo axis in drive system (fluctuating part) 1 to 4
 Accumulated regeneration of servo axis in drive system (fluctuating part) 1 to 4
 Accumulated consumption of spindle in drive system (fluctuating part) 1 to 4
 Accumulated regeneration of spindle in drive system (fluctuating part) 1 to 4
[Related signals]
(1) Power consumption computation: Consumption accumulation ON 1 to 4 (IPCEI1 to 4: X700 to 3)
(2) Power consumption computation: Accumulated consumption of entire drive system 1 to 4 (DTIPC1 to 4: R122 to 9)
(3) Power consumption computation: Accumulated consumption of devices other than drive system 1 to 4 (NDIPC1 to 4:
R130 to 7)
(4) Power consumption computation: Consumption of devices other than drive system (NDPC: R304, 5)
(5) Power consumption computation: Drive system's fixed consumption correction (DFPCC: R306, 7)
Cont.
Signal name
A
CRT changeover completion
[Function]
When one setting display device is used as the display device of multiple control devices, this signal is used to inform the
controller that it has been switched as its own display device.
[Operation]
When this signal is turned ON, the currently selected screen is displayed at the rising edge. For the setting and display unit
screen, the display screen of the control device before switching remains. Therefore, input this signal to switch to the own
screen display.
[Timing chart]
CRT changeover
CRT changeover completion
(CRTFN)
Screen display
Other controller
Local
Screen display on other controller
Abbrev.
Common ($)
IPCE1 to 4
Y724 to 7
Abbrev.
Common ($)
CRTFN
Y728
At least 100 ms
Or more required
Local screen display
363
IB-1501616-D