4 Explanation of Interface Signals
4.3 PLC Output Signals (Bit Type: Y***)
Cont.
Signal name
A
Spindle OFF mode
[Function]
This function is used to check the program by moving the machine without rotating the spindle.
[Operation]
<Synchronized tapping mode>
By turning on the spindle OFF mode, the spindle does not turn ON or rotate.
Even if the spindle OFF mode is changed during the synchronized tapping mode, the operation does not change until the
synchronized tapping mode is turned OFF. It is recommended to turn ON this signal from the beginning of operation.
<Asynchronous tapping mode>
 During synchronous (every revolution) feed
In addition to M03, M04 processing and dry run signal, turn ON the spindle OFF mode. The program proceeds when the
signal is turned ON.
 During asynchronous feed (every minute) feed
The program proceeds even if the spindle OFF mode is not turned ON.
<Thread cutting>
When the parameter "#1279 ext15/bit4" (Dry run OFF during thread cutting) is set to "1", the dry run is disabled for thread
cutting. However, when the "Spindle OFF mode" signal is ON, dry run is enabled regardless of the parameter setting, and
the status of dry run is determined by the "Dry run" signal.
ext15/bit4
0
0
1
1
1
[Related signals]
(1) Dry run (DRN: YC15)
Cont.
Signal name
A
Longitudinal hole drilling axis selection
[Function]
This signal is used to specify the hole drilling axis for the longitudinal hole drilling fixed cycle (G87, G88, G88.1, and G89).
[Operation]
When this signal is OFF (0), the X axis becomes the hole drilling axis.
When this signal is ON (1), the Y axis becomes the hole drilling axis.
When a hole edge chamfering cycle is executed while this signal is ON, the program error (P188) occurs.
Cont.
Signal name
A
Tap retract possible state cancel
[Function]
Turning ON this signal allows to move the axis, both automatically and manually, without tap retract.
This signal is used when it is judged that the spindle rotation due to tap retract is dangerous, such as when the tap is
damaged.
[Operation]
Turning this signal ON turns OFF the "Tap retract possible" signal (TRVE).
[Related signals]
(1) Tap retract (TRV: YC5C)
(2) Tap retract possible (TRVE: XCA5)
IB-1501616-D
Abbrev.
$1
$2
YCD3
YE13
Dry run
Spindle OFF mode
0
0/1
1
0/1
0
0/1
1
0
1
1
Abbrev.
$1
$2
-
YCD4
YE14
Abbrev.
$1
$2
TRVEC
YCD6
YE16
468
$3
$4
$5
$6
YF53
Y1093
Y11D3
Y1313
Thread cutting motion
Command speed
Dry run speed
Command speed
Command speed
Dry run speed
$3
$4
$5
$6
YF54
Y1094
Y11D4
Y1314
$3
$4
$5
$6
YF56
Y1096
Y11D6
Y1316
$7
$8
Y1453
Y1593
$7
$8
Y1454
Y1594
$7
$8
Y1456
Y1596