Mitsubishi Electric M80V Series Manual page 268

Hide thumbs Also See for M80V Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Interface Manual
4 Explanation of Interface Signals
4.1 PLC Input Signals (Bit Type: X***)
Cont.
Signal name
A
Spindle servo-ON
[Function]
This signal is a signal output from spindle controller (spindle drive) with high-speed serial coupling specifications, and
informs that the spindle is in the position control (synchronous tap control, etc.) state.
[Operation]
The "Spindle servo-ON" signal (SSA) turns ON when the spindle is ready (SMA signal is ON), the servo-ON command has
been transferred from the controller to the spindle controller, and the spindle controller is in the servo-on state.
Note that this signal turns ON during rotation by the "Spindle forward run start" (SRN) or the "Spindle reverse run start"
(SRI) other than during spindle synchronization, and during spindle orientation.
This signal (SSA) turns OFF when the servo-ON command is canceled.
Spindle servo-on command
(*1)
Spindle servo-on (SSA)
(*1) The spindle servo-ON command is output from the controller to the spindle controller. It is mainly output during syn-
chronous tap control.
Note
(1) While the "Spindle servo-ON" signal is ON, the "Spindle forward run start" (SRN), "Spindle reverse run start" (SRI),
and "Spindle orientation command" (ORC) signals are ignored.
(2) This signal is valid only for systems that are high-speed serially coupled to the spindle controller.
Cont.
Signal name
A
In spindle forward run
[Function]
This signal is output from the spindle controller (spindle drive) with high-speed serial coupling specifications and informs
that the spindle is rotating in the forward direction.
[Operation]
The "In spindle forward run" signal (SSRN) turns ON when the spindle motor is rotating in the forward direction.
This signal also turns ON if the spindle motor is rotating in the forward direction during orientation or synchronous tap.
Spindle motor speed
In spindle forward run
(SSRN)
Note
(1) The "In spindle forward run" signal (SSRN) turns ON and OFF while the spindle motor is in the stop state with servo
rigidity during oriented motion or synchronous tap.
(2) This signal is valid only for systems that are high-speed serially coupled to the spindle controller.
Abbrev.
1stSP
2ndSP
SSA
X1891
X18F1
Abbrev.
1stSP
2ndSP
SSRN
X1893
X18F3
255
3rdSP
4thSP
5thSP
6thSP
X1951
X19B1
X1A11
X1A71
3rdSP
4thSP
5thSP
6thSP
X1953
X19B3
X1A13
X1A73
7thSP
8thSP
X1AD1
X1B31
7thSP
8thSP
X1AD3
X1B33
IB-1501616-D

Advertisement

Table of Contents
loading

This manual is also suitable for:

M800v series

Table of Contents