M800V/M80V Series PLC Interface Manual
4 Explanation of Interface Signals
4.4 PLC Output Signals (Data Type: R***)
Cont.
Signal name
MES interface library:
A
Cycle time
[Function]
The cycle time is stored here. The unit is [ms].
[Operation]
This signal specifies the time (ms) from cycle start until the M code registered in "#8001 WRK COUNT M" is performed.
When "0" is set in "#8001 WRK COUNT M", this signal specifies the time (ms) from cycle start until M02 or M30 is
performed.
When the cycle time exceeds "499:59:59.999", "1799999999" is set.
When MES interface library function is invalid, this signal is set to "0".
Cont.
Signal name
MES interface library:
A
Program number at machining start
[Function]
The program number at the time of the machining start is stored here.
[Operation]
When the machining is completed, this sets the ASCII code (hexadecimal number) corresponding to the program number
of that machining start automatically.
When MES interface library function is invalid, this signal is set to "0".
Cont.
Signal name
MES interface library:
A
N number at machining start
[Function]
The N number at the time of the machining start is stored here.
[Operation]
When the machining is completed, this sets the N number of that machining start automatically.
When MES interface library function is invalid, this signal is set to "0".
Cont.
Signal name
MES interface library:
A
B number at machining start
[Function]
The B number at the time of the machining start is stored here.
[Operation]
When the machining is completed, this sets the B number of that machining start automatically.
When MES interface library function is invalid, this signal is set to "0".
Cont.
Signal name
MES interface library:
A
Spindle 1 maximum load
[Function]
The maximum current of the 1st spindle at the time of the machining completion is stored here.
[Operation]
When the machining is completed, the maximum current of the 1st spindle since the machining start is automatically set.
The maximum current is set by 1% increments regardless of the value of "#1256 set28/bit2" (Change current FB (load)
output unit).
When MES interface library function is invalid, this signal is set to "0".
Abbrev.
$1
$2
R14704,
R14954,
R15204,
5
5
Abbrev.
$1
$2
R14706
R14956
R15206
to
to
R14721
R14971
R15221
Abbrev.
$1
$2
R14722,
R14972,
R15222,
3
3
Abbrev.
$1
$2
R14724,
R14974,
R15224,
5
5
Abbrev.
$1
$2
R14726 R14976 R15226 R15476 R15726 R15976 R16226 R16476
613
$3
$4
$5
$6
R15454,
R15704,
R15954,
5
5
5
5
$3
$4
$5
$6
R15456
R15706
R15956
to
to
to
to
R15471
R15721
R15971
$3
$4
$5
$6
R15472,
R15722,
R15972,
3
3
3
3
$3
$4
$5
$6
R15474,
R15724,
R15974,
5
5
5
5
$3
$4
$5
$6
$7
$8
R16204,
R16454,
5
5
$7
$8
R16206
R16456
to
to
R16221
R16471
$7
$8
R16222,
R16472,
3
3
$7
$8
R16224,
R16474,
5
5
$7
$8
IB-1501616-D