M800V/M80V Series PLC Interface Manual
4 Explanation of Interface Signals
4.6 Explanation of ZR Device
Cont.
Signal name
Diagnosis data output:
A
Motor insulation resistance
(motor)
[Function] [Operation]
The present insulation resistance of the motor is set in the register.
If the insulation resistance is less than 1MΩ, "0" is set.
If the insulation resistance is 100MΩ or greater, "100" is set.
If your drive unit does not support this function, or if the data has not been obtained from the drive unit, "-1" (0xFFFFFFFF)
is set in the register.
[Caution]
(1) The data is in the units of 1.0MΩ.
(2) The data format is signed binary.
(3) The data of servo axes (NC and PLC axes) is output to these registers, in the order of the axis specified with the base
axis specification parameter.
(4) The effective value can be obtained only when the drive unit is MDS-E/EH Series (when the drive unit S/W version is
A3 or later, and the H/W supports the insulation degradation detection function).
Cont.
Signal name
Diagnosis data output:
A
Motor insulation resistance (motor)
[Function] [Operation]
The present insulation resistance of the motor is set in the register.
If the insulation resistance is less than 1MΩ, "0" is set.
If the insulation resistance is 100MΩ or greater, "100" is set.
If your drive unit does not support this function, or if the data has not been obtained from the drive unit, "-1" (0xFFFFFFFF)
is set in the register.
[Caution]
(1) The data is in the units of 1.0MΩ.
(2) The data format is signed binary.
(3) The effective value can be obtained only when the drive unit is MDS-E/EH Series (when the drive unit S/W version is
A3 or later, and the H/W supports the insulation degradation detection function).
Cont.
Signal name
A
Diagnosis data output: Automatic log clear time
[Function] [Operation]
Set the length of time before automatic log clear takes place.
[Caution]
(1) The data is in the units of 1.0 hour.
(2) If this signal is unspecified, the default time (24 hours) is applied.
IB-1501616-D
Abbrev.
1st axis
2nd axis
ZR12784
ZR12786
ZR12785
ZR12787
9th axis 10th axis 11th axis 12th axis 13th axis 14th axis 15th axis 16th axis
ZR12800
ZR12802
ZR12801
ZR12803
17th axis 18th axis 19th axis 20th axis 21th axis 22th axis 23th axis 24th axis
ZR12816
ZR12818
ZR12817
ZR12819
25th axis 26th axis 27th axis 28th axis 29th axis 30th axis 31th axis 32th axis
ZR12832
ZR12834
ZR12833
ZR12835
Abbrev.
1stSP
2ndSP
ZR12848
ZR12850
ZR12849
ZR12851
688
3rd axis
4th axis
5th axis
ZR12788
ZR12790
ZR12792
ZR12789
ZR12791
ZR12793
ZR12804
ZR12806
ZR12808
ZR1280
ZR12807
ZR12809
ZR12820
ZR12822
ZR12824
ZR12821
ZR12823
ZR12825
ZR12836
ZR12838
ZR12840
ZR12837
ZR12839
ZR12841
3rdSP
4thSP
5thSP
ZR12852
ZR12854
ZR12856
ZR12853
ZR12855
ZR12857
Abbrev.
Common ($)
ZR12945
6th axis
7th axis
8th axis
ZR12794
ZR12796
ZR12798
ZR12795
ZR12797
ZR12799
ZR12810
ZR12812
ZR12814
ZR12811
ZR12813
ZR12815
ZR12826
ZR12828
ZR12830
ZR12827
ZR12829
ZR12831
ZR12842
ZR12844
ZR12846
ZR12843
ZR12845
ZR12847
6thSP
7thSP
8thSP
ZR12858
ZR12860
ZR12862
ZR12859
ZR12861
ZR12863