M800V/M80V Series PLC Interface Manual
4 Explanation of Interface Signals
4.4 PLC Output Signals (Data Type: R***)
 Pot No. expansion (R10600/bit2)
This function allows pot head No. for each magazine to be set arbitrarily.
[When the pot head No. is set to "No arbitrary setting"]
The pot head No. for each magazine is "1" or "0", depending on the setting of the "magazine No. start value" of the ATC
control parameter (R10600/bit1).
(Example 1) When the magazine No. starts with "1" ("R10600/bit1" is set to "0")
Set the following R registers.
R10600 : 0x0000
o Number of digits for tool No. to be displayed : T4-digit
o Magazine No. start value
o Pot No. expansion
o Number of tools per magazine : No arbitrary setting
R10610 : 0x000C
o Number of tools for magazine 1 : 12
(Example 2) When the magazine No. starts with "0" ("R10600/bit1" is set to "1")
Set the following R registers.
R10600 : 0x0002
o Number of digits for tool No. to be displayed : T4-digit
o Magazine No. start value
o Pot No. expansion
o Number of tools per magazine : No arbitrary setting
R10610 : 0x000C
o Number of tools for magazine 1 : 12
IB-1501616-D
: 1-start magazine
: No arbitrary setting
: 0-start magazine
: No arbitrary setting
606