Mitsubishi Electric M80V Series Manual page 332

Hide thumbs Also See for M80V Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Interface Manual
4 Explanation of Interface Signals
4.2 PLC Input Signals (Data Type: R***)
[Related signals]
(1) User macro output #1133, #1134, #1135 (R6374/6375, R6376/6377, R6378/6379)
(2) User macro input #1032, #1033, #1034, #1035 (R6436/6437, R6438/6439, R6440/6441, R6442/66443)
Cont.
Signal name
A
User macro output #1133 (NC -> PLC)
[Function]
This is interface function used to coordinate user PLC to user macro.
[Operation]
When a value is set in the system variable #1133 with the user macro, it is output to the corresponding file registers Rn
and Rn+1 of the user PLC, and the value can be referenced by the user PLC.
(Example)
User macro program
#1133 = 1000
[Related signals]
(1) User macro output #1132, #1134, #1135 (R6372/6373, R6376/6377, R6378/6379)
(2) User macro input #1032, #1033, #1034, #1035 (R6436/6437, R6438/6439, R6440/6441, R6442/66443)
Cont.
Signal name
A
User macro output #1134 (NC -> PLC)
[Function] [Operation]
The function, operation, etc. are the same as those of "User macro output #1133".
Cont.
Signal name
A
User macro output #1135 (NC -> PLC)
[Function] [Operation]
The function, operation, etc. are the same as those of "User macro output #1133".
Abbrev.
$1
$2
R6374, 5 R6382, 3 R6390, 1 R6398, 9 R6406, 7 R6414, 5 R6422, 3 R6430, 1
Sequence program
ACT
1000 is input in D100 and 101 when the ACT signal turns ON.
Abbrev.
$1
$2
R6376, 7 R6384, 5 R6392, 3 R6400, 1 R6408, 9 R6416, 7 R6424, 5 R6432, 3
Abbrev.
$1
$2
R6378, 9 R6386, 7 R6394, 5 R6402, 3 R6410, 1 R6418, 9 R6426, 7 R6434, 5
319
$3
$4
$5
$6
DMOV
R6374 D100
$3
$4
$5
$6
$3
$4
$5
$6
$7
$8
$7
$8
$7
$8