M800V/M80V Series PLC Interface Manual
4 Explanation of Interface Signals
4.1 PLC Input Signals (Bit Type: X***)
Cont.
Signal name
A
NC axis/PLC axis switchover invalid status
[Function]
This signal indicates that the NC axis/PLC axis switchover is disabled on the axis that is subject to the NC axis/PLC axis
switchover.
This signal is available for each control axis.
[Operation]
This signal turns ON when the axis for which the NC axis/PLC axis switchover is valid is under the following conditions.
When the NC axis/PLC axis switchover is performed while this signal is ON, the operation error (M01 1250) occurs.
While the axis is moving(*1)
When the movement is stopped by the override zero or feed hold
During the servo OFF
While the axis is being removed
While the axis is stopped for interlock
During the current limit
During the droop cancel
During the H/W OT or soft limit
During the manual machine lock
The reference axis or superimposed axis that is under the control axis superimposition
The reference axis or synchronized axis that is under the control axis synchronization between part systems
The chopping axis during the chopping
The rotary tool axis during the tool spindle synchronization II (polygon)
The workpiece axis during the tool spindle synchronization II (hobbing)
The axis of the part system which is during the high-speed machining mode II/high-speed high-accuracy control II
(*1) When a movement command is given to multiple axes in the same program block, even if the movement of the swi-
tchover target axis is completed and stopped, the switchover is disabled if the other axes are still moving.
[Related signals]
(1) NC axis/PLC axis switchover in process (NPCHGMOD1 to 8: XBC0 to 7)
(2) NC axis/PLC axis switchover request (NPCHGREQ1 to 8: YBC0 to 7)
Cont.
Signal name
A
NC axis/PLC axis switchover n-th axis in process
[Function]
This signal notifies that the NC axis/PLC axis switching axis is in a controllable state as a PLC axis.
This signal is available for each control axis.
[Operation]
This signal turns OFF while the NC axis is controlled and turns ON while the PLC axis is controlled.
[Related signals]
(1) NC axis/PLC axis switchover invalid status (NPCHGIS1 to 8: XBA0 to 7)
(2) NC axis/PLC axis switchover request (NPCHGREQ1 to 8: YBC0 to 7)
IB-1501616-D
Abbrev.
$1
NPCHGIS1
XBA0 to 7
XBA8 to F
to 8
Abbrev.
$1
NPCHG-
XBC0 to 7
XBC8 to F
MOD1 to 8
190
$2
$3
$4
XBB0 to 7
XBB8 to F
$2
$3
$4
XBD0 to 7
XBD8 to F