M800V/M80V Series PLC Interface Manual
4 Explanation of Interface Signals
4.4 PLC Output Signals (Data Type: R***)
Cont.
Signal name
A
User macro input #1033 (PLC -> NC)
[Function]
This provides interface function used to coordinate user PLC to user macro.
[Operation]
The data set in file registers Rn and Rn+1 with the user PLCs, can be referred to on the user macro side with the user
macro system variables #1033.
(Example)
Sequence program
ACT
DMOV K1000
ACT
WOR
[Related signals]
(1) User macro input #1032, #1034, #1035 (R6436/6437,R6440/6441,R6442/6443)
(2) User macro output #1132, #1133, #1134, #1135 (R6372/6373,R6374/6375,R6376/6377,R6378/6379)
Cont.
Signal name
A
User macro input #1034 (PLC -> NC)
[Function] [Operation]
The function, operation, etc. are the same as those of "User macro input #1033".
Cont.
Signal name
A
User macro input #1035 (PLC -> NC)
[Function] [Operation]
The function, operation, etc. are the same as those of "User macro input #1033".
Abbrev.
$1
$2
R6438, 9 R6446, 7 R6454, 5 R6462, 3 R6470, 1 R6478, 9 R6486, 7 R6494, 5
R6438
R6436
K1
R6436
Set 1 in #1000.
Abbrev.
$1
$2
R6440, 1 R6448, 9 R6456, 7 R6464, 5 R6472, 3 R6480, 1 R6488, 9 R6496, 7
Abbrev.
$1
$2
R6442, 3 R6450, 1 R6458, 9 R6466, 7 R6474, 5 R6482, 3 R6490, 1 R6498, 9
591
$3
$4
$5
User macro program
IF [#1000 EQ 0] GOTO 100
#100 = #1033
N100
The #1033(R6438, R6439) data is read into #100
Other than when #1000 is set to 0.
$3
$4
$5
$3
$4
$5
$6
$7
$8
$6
$7
$8
$6
$7
$8
IB-1501616-D