M800V/M80V Series PLC Interface Manual
4 Explanation of Interface Signals
4.4 PLC Output Signals (Data Type: R***)
System vari-
R register
able
#40083
R204325
:
:
#40097
R20449
(*1) The interfering model coordinate system offset is the sum of interfering model coordinate system offsets 1 and 2.
Cont.
Signal name
Diagnosis data output: Select axis for servomotor insulation
A
degradation detection (PLC axis)
[Function]
This signal is used to select the PLC axis for insulation resistance measurement.
[Operation]
When the control starts measuring the motor insulation resistance, the measurement starts on the axis for which the signal
is ON.
F E
D C
B A
9
[Related signals]
(1) Diagnosis data output: Motor insulation degradation detection request (IDDD: R20481)
Item
2nd interfering object: Specify-
ing disabled object with interfer-
ence check III
16th interfering object: Specify-
ing disabled object with interfer-
ence check III
8
7 6
5
4
3
2
1
0
Details
Select an interfering object that
you do not check the interfer-
ence with the 2nd interfering ob-
ject.
bit0: Disable 1st interfering ob-
ject
bit1: Disable 2nd interfering ob-
ject (inaction data)
:
bitF: Disable 16th interfering
object
Select an interfering object that
you do not check the interfer-
ence with the 16th interfering
object.
bit0: Disable 1st interfering ob-
ject
bit1: Disable 2nd interfering ob-
ject
:
bitF: Disable 16th interfering
object (inaction data)
Abbrev.
Common ($)
SVIDDDAX
R20450
Degradation detection axis selection 1st axis
Degradation detection axis selection 2nd axis
:
Degradation detection axis selection 16th axis
623
Setting range (unit)
Upper: System variable
Lower: R register
0 to 65535 (decimal)
0x0000 to 0xFFFF (hexadeci-
mal)
0 to 65535 (decimal)
0x0000 to 0xFFFF (hexadeci-
mal)
IB-1501616-D