Mitsubishi Electric M80V Series Manual page 292

Hide thumbs Also See for M80V Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Interface Manual
4 Explanation of Interface Signals
4.2 PLC Input Signals (Data Type: R***)
Cont.
Signal name
A
Clock data Year/Month
A
Clock data Date/Hour
A
Clock data Minute/Second
[Function]
The year, month, date, hour, minute, second and millisecond data is informed by the controller to the PLC as the current
clock information.
[Operation]
The date and time data is output as shown below. The data is output as binary data.
R11
Month
R12
Hour
R13
Second
(Example) For October 26, 2002, 14:56:36.
R11 ... 0 0 0 0 1 0 1 0 0 0 0 0 0 0 1 0 = 0A 02H
October
R12 ... 0 0 0 0 1 1 1 0 0 0 0 1 1 0 1 0 = 0E1AH
14 hundred hours 26th day
R13 ... 0 0 1 0 0 1 0 0 0 0 1 1 1 0 0 0 = 2438H
36 seconds
Note
(1) The time is displayed with the 24-hour system.
(2) The data and time are set with the [TIME] screen on the setting and display unit.
Cont.
Signal name
A
CNC software version code
[Function]
This indicates the CNC software version.
[Operation]
The version displayed at "MP" on the [Software Directory] screen is indicated.
The file registers R16 to R19 are set to the following data.
(Example)
BND-2051W000-A0B
(1)
Item
Model function No.
(1)
Serial No.
(2)
Version
(3)
-
-
(*1) If the version is a 2-digit number, bits F to 8 of R16 are set to "20H".
Year
Date
Minute
2002
56 minutes
(2) (3)
File register
R19
Binary
R18
Binary
bits F to 8 of R17
ASCII code
bits 7 to 0 of R17
ASCII code
bits F to 8 of R16
ASCII code(*1)
bits 7 to 0 of R16
Always 20H
Abbrev.
Common ($)
R11
R12
R13
Abbrev.
Common ($)
R16 to 9
Type
0803H = 2051 (decimal)
0000H = 000
41H ("A")
30H ("0")
42H ("B")
(Blank)
279
Example
IB-1501616-D

Advertisement

Table of Contents
loading

This manual is also suitable for:

M800v series

Table of Contents