Mitsubishi Electric M80V Series Manual page 356

Hide thumbs Also See for M80V Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Interface Manual
4 Explanation of Interface Signals
4.2 PLC Input Signals (Data Type: R***)
Cont.
Signal name
MES interface library: Database operation reception regis-
A
[Function]
The reception status of the database for the database operation from the NC is stored here.
[Operation]
bit0: "1" is set while accepting database operations for the machining result table.
bit1: "1" is set while accepting database operations for the alarm history table.
bit2: "1" is set while accepting database operations for the arbitrary information accumulation table.
"0" is set when the database operation is completed.
[Related signals]
(1) MES interface library: Database operation request register (R14590)
(2) MES interface library: Database operation result register (R14592 to R14597)
Cont.
Signal name
A
MES interface library: Database operation result register
[Function]
The result of the database operation is stored here.
[Operation]
0: Normal end
Other than 0: Occurrence of an error
Which registers to be used varies for each data table of the target database operations.
R14592 R14593: Notifies the result of the database operation for the machining result table.
R14594 R14595: Notifies the result of the database operation for the alarm history table.
R14596 R14597: Notifies the result of the database operation for the arbitrary information accumulation table.
[Related signals]
(1) MES interface library: Database operation request register (R14590)
(2) MES interface library: Database operation reception register (R14591)
The timing chart for the request register, the reception register and the result register is as follows.
Example: Registration operation
Request register
Registration data
Reception register
Result register
(R14592 to R14597)
ter
(1) Issue the
registration request
(R14590)
Data registration processing
(R14591)
Registration operation in process
Abbrev.
Common ($)
R14591
Abbrev.
Common ($)
R14592 to
R14597
(3) Request register is turned
OFF automatically after
detecting the request receipt.
(2) Reception register
turns ON after detecting
the request
343
(4) When the registration
process is completed and the
requestor confirms the
reception, the process result is
set and reception register
automtically turns OFF.
Processing result
IB-1501616-D