Mitsubishi Electric M80V Series Manual page 545

Hide thumbs Also See for M80V Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Interface Manual
4 Explanation of Interface Signals
4.4 PLC Output Signals (Data Type: R***)
Cont.
Signal name
A
APLC version
[Function]
This signal indicates APLC software version.
[Operation]
File register R240 to R243 is as the following data.
R240 to R243 is as the following data.
(Example)
BND-1003W400-A0B
(1)
(2) (3)
Item
Model function No.
(1)
Serial No.
(2)
Version
(3)
-
-
(*1) If the version is 1-digit No., set the version in bits 7 to 0 of R242, and set "00H" in bits F to 8 of R242 and bits 7 to 0
of R243.
(*2) Always set "FFH" in bits F to 8 of R243. If "FFH" is not set, it will not be displayed correctly.
IB-1501616-D
File register
R240
Binary
R241
Binary
bits 7 to 0 of R242
ASCII code
bits F to 8 of R242
ASCII code(*1)
bits 7 to 0 of R243
ASCII code(*1)
bits F to 8 of R243
Always FFH(*2)
532
Abbrev.
Common ($)
R240 to 3
Type
Example
1003=03EBH
400=0190H
A=41H
0=30H
B=42H
FFH

Advertisement

Table of Contents
loading

This manual is also suitable for:

M800v series

Table of Contents