4 Explanation of Interface Signals
4.3 PLC Output Signals (Bit Type: Y***)
Cont.
Signal name
A
Handle mode
[Function]
Handle feed operation mode (manual operation) is selected.
[Operation]
When the "Handle mode" signal (H) is turned ON, handle feed mode is selected.
Axis motion starts when the manual pulse generator hand wheel is rotated after axis is selected by the "n-th handle axis
selection code" (HSn1 to HSn16) and the "n-th handle valid" (HSnS), and this signal is turned ON. Speed of the axis
motion depends on setting of feedrate magnification (MP1 to 4).
When the operation mode conflicts with any other mode or when no mode is selected, the NC alarm (operation error (M01
0101) occurs.
Automatic operation handle interruption function is valid when the "Handle mode" signal is turned ON while the automatic
operation mode is selected.
[Related signals]
(1) 1st handle axis selection code (HS11 to 116: YC40), 1st handle valid (HS1S: YC47)
(2) 2nd handle axis selection code (HS21 to HS216: YC48), 2nd handle valid (HS2S: YC4F):
Valid only for handle 2-axis specification.
(3) 3rd handle axis selection code (HS31 to 316: YC50), 3rd handle valid (HS3S: YC57)
Valid only for handle 3-axis specification.
(4) Handle/Incremental feed magnification code m (MP1 to 4: YC80 to YC82)
Cont.
Signal name
A
Incremental mode
[Function]
Incremental feed mode for manual operation is selected.
[Operation]
When the "Incremental mode" signal (S) is turned ON, incremental feed mode is selected.
Every time the "Incremental mode" (S) is turned ON and the feed axis selection signal (+J1 to 8, -J1 to 8) of the desired
axis is turned ON, axis movement is performed. Axis movement depends on setting of the "Handle/Incremental feed
magnification code m" (MP1 to 4) at that time.
The movement speed at that time is the rapid traverse speed when the "Rapid traverse" signal (RT) is ON, and the manual
feedrate (*JV1 to *JV16) when the signal (RT) is OFF.
When the operation mode conflicts with any other mode or when no mode is selected, the NC alarm (operation error (M01
0101)) occurs.
Note
(1) The incremental mode is also called as step mode.
[Related signals]
(1) Handle/Incremental feed magnification code m (MP1 to 4: YC80 to YC82)
(2) Feed axis selection (+J1 to 8: Y8E0, -J1 to 8: Y900)
(3) Manual feedrate code m (*JV1 to *JV16: YC70)
(4) Rapid traverse (RT: YC26)
IB-1501616-D
Abbrev.
$1
$2
H
YC01
YD41
YE81
Abbrev.
$1
$2
S
YC02
YD42
YE82
404
$3
$4
$5
$6
YFC1
Y1101
Y1241
$3
$4
$5
$6
YFC2
Y1102
Y1242
$7
$8
Y1381
Y14C1
$7
$8
Y1382
Y14C2