Mitsubishi Electric M80V Series Manual page 295

Hide thumbs Also See for M80V Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Interface Manual
4 Explanation of Interface Signals
4.2 PLC Input Signals (Data Type: R***)
Cont.
Signal name
A
Emergency stop cause
[Function]
The causes of emergency stop are shown with bit correspondence.
[Operation]
The cause of the emergency stop state is shown as follows with bit correspondence.
If there are multiple causes, the multiple bits corresponding to each cause are output.
The bit of this signal that is set to "0" is the emergency stop cause.
File register
F E D C B A 9 8
(R)
IB-1501616-D
Abbrev.
7 6 5 4 3 2 1 0
282
Common ($)
R69
Bit
EMG Emergency stop ○○○○

Advertisement

Table of Contents
loading

This manual is also suitable for:

M800v series

Table of Contents