M800V/M80V Series PLC Interface Manual
4 Explanation of Interface Signals
4.6 Explanation of ZR Device
Cont.
A
Data I/O register for MES interface library (N number at machining start)
[Function]
This signal is used to set the sequence number after the update at the time of the update operation.
The sequence number extracted from the database is stored at the time of the extraction operation.
[Operation]
For the update operation, specify the value of the sequence number.
For the extraction operation, the sequence number is stored.
Cont.
A
Data I/O register for MES interface library (B number at machining start)
[Function]
This signal is used to set the block number after the update at the time of the update operation.
The block number extracted from the database is stored at the time of the extraction operation.
[Operation]
For the update operation, specify the value of the block number.
For the extraction operation, the block number is stored.
Cont.
A
Data I/O register for MES interface library (Spindle 1 maximum load)
[Function]
This signal is used to set the 1st spindle's maximum current value after the update at the time of the update operation.
The 1st spindle's maximum current value extracted from the database is stored at the time of the extraction operation.
[Operation]
For the update operation, specify the maximum current value [%] of the 1st spindle.
For the extraction operation, the maximum current value [%] of the 1st spindle is stored.
Cont.
A
Data I/O register for MES interface library (Spindle 2 maximum load)
[Function]
This signal is used to set the 2nd spindle's maximum current value after the update at the time of the update operation.
The 2nd spindle's maximum current value extracted from the database is stored at the time of the extraction operation.
[Operation]
For the update operation, specify the maximum current value [%] of the 2nd spindle.
For the extraction operation, the maximum current value [%] of the 2nd spindle is stored.
Cont.
A
Data I/O register for MES interface library (Power consumption amount)
[Function]
This signal is used to set the power consumption amount after the update at the time of the update operation.
The consumption amount extracted from the database is stored at the time of the extraction operation.
[Operation]
For the update operation, specify the value of power consumption amount [Wh].
For the extraction operation, the power consumption amount [Wh] is stored.
Cont.
A
Data I/O register for MES interface library (Power regeneration amount)
[Function]
This signal is used to set the power regeneration amount after the update at the time of the update operation.
The power regeneration amount extracted from the database is stored at the time of the extraction operation.
[Operation]
For the update operation, specify the value of power regeneration amount [Wh].
For the extraction operation, the power regeneration amount [Wh] is stored.
IB-1501616-D
Signal name
Signal name
Signal name
Signal name
Signal name
Signal name
678
Abbrev.
Common ($)
ZR10496, 7
Abbrev.
Common ($)
ZR10498, 9
Abbrev.
Common ($)
ZR10500
Abbrev.
Common ($)
ZR10501
Abbrev.
Common ($)
ZR10502, 3
Abbrev.
Common ($)
ZR10504, 5