Mitsubishi Electric M80V Series Manual page 537

Hide thumbs Also See for M80V Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Interface Manual
4 Explanation of Interface Signals
4.3 PLC Output Signals (Bit Type: Y***)
Cont.
Signal name
A
Laser: Axis stop time with beam ON monitoring OFF
[Function] [Operation]
When the axis movement stops while the laser beam is ON, if the time set by the parameter "#90005 lsr_max_stop_t"
(Maximum stop time with beam ON) has passed since the axis movement stop, the laser beam is automatically turned
OFF.
By turning this signal ON, the beam irradiation can be continued even after the time set by the parameter #90005 has
passed.
This signal is used to calibrate the output of the laser beam.
[Caution]
(1) Turn this signal ON only while the output is calibrated. In the other cases, turn it OFF for safety.
(2) The operation error (M95 9509) occurs while this signal is ON.
When this signal is ON, even if the beam is ON and the axis movement still stops after the time set by the parameter
#90005 has passed, the laser beam is not turned OFF. The operation error also does not occur.
[Related signals]
(1) Laser: Laser beam irradiation ON (Y1CA7)
IB-1501616-D
Abbrev.