Mitsubishi Electric M80V Series Manual page 353

Hide thumbs Also See for M80V Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Interface Manual
4 Explanation of Interface Signals
4.2 PLC Input Signals (Data Type: R***)
Cont.
EcoMonitorLight connection: Station #1 to #16 number of recep-
A
EcoMonitorLight connection: Station #1 to #16 maximum number
A
of successive reception errors
EcoMonitorLight connection: Station #1 to #16 number of trans-
A
EcoMonitorLight connection: Station #1 to #16 maximum number
A
of successive transmission errors
[Function]
This signal stores the number of reception errors, maximum number of successive reception errors, the number of
transmission errors, and maximum number of successive transmission errors of EcoMonitorLight.
No. of reception er-
Station No.
Station #1
R14200
Station #2
R14210
Station #3
R14220
Station #4
R14230
Station #5
R14240
Station #6
R14250
Station #7
R14260
Station #8
R14270
Station #9
R14280
Station #10
R14290
Station #11
R14300
Station #12
R14310
Station #13
R14320
Station #14
R14330
Station #15
R14340
Station #16
R14350
[Operation]
The number of reception errors and the number of transmission errors are updated when an error occurs on the
communication with EcoMonitorLight.
The increment stops when the reception or transmission completes without an error.
The maximum number of successive reception errors is updated when the number of successive communication error is
larger than the value of R14201 (for the case of station #1).
The maximum number of successive transmission error is updated when the number of successive communication error
is larger than the value of R14203 (for the case of station #1).
Cont.
Signal name
A
EcoMonitorLight connection: Completion bit
[Function]
This bit indicates the completion of the power value collecting function.
[Operation]
Bit0 is set to "1" upon completion of collection.
The bit is cleared to zero in the next cycle.
IB-1501616-D
Signal name
tion errors
mission errors
Device No.
Max. No. of successive
rors
reception errors
R14201
R14211
R14221
R14231
R14241
R14251
R14261
R14271
R14281
R14291
R14301
R14311
R14321
R14331
R14341
R14351
Abbrev.
Common ($)
R14200 to
R14350
R14201 to
R14351
R14202 to
R14352
R14203 to
R14353
No. of transmission
errors
R14202
R14212
R14222
R14232
R14242
R14252
R14262
R14272
R14282
R14292
R14302
R14312
R14322
R14332
R14342
R14352
Abbrev.
Common ($)
R14400
340
Max. No. of successive
transmission errors
R14203
R14213
R14223
R14233
R14243
R14253
R14263
R14273
R14283
R14293
R14303
R14313
R14323
R14333
R14343
R14353

Advertisement