Mitsubishi Electric M80V Series Manual page 335

Hide thumbs Also See for M80V Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Interface Manual
4 Explanation of Interface Signals
4.2 PLC Input Signals (Data Type: R***)
Cont.
Signal name
Spindle synchronization: Phase offset
A
data
[Function]
With the spindle phase shift amount calculation function, the phase error of the reference spindle and synchronized
spindle is obtained and memorized by turning the PLC signal ON at executing the spindle synchronization. The
synchronized spindle can be rotated with the handle during the spindle phase shift calculation, so the phase relation
between two spindles can be adjusted by seeing.
If the "Spindle phase synchronous control" signal (SPPHS) is input while the "Phase offset request" signal (SSPHF) is ON,
the phase error will be aligned based on the position shifted by the memorized phase shift amount.
Such operation makes the phase alignment easy when clamping a profile material over.
[Operation]
The phase error memorized by the phase shift calculation is output.
Unit: 360°/4096
Note
(1) Refer to the signal of the 1st spindle when the parameter "#1440 multi_sp_syn" (Multiple spindle synchronization
valid) is set to "0".
(2) Refer to the synchronized spindle's signal when the parameter "#1440 multi_sp_syn" (Multiple spindle synchroniza-
tion valid) is set to "1".
(3) This data is output only during the spindle synchronous control.
[Related signals]
(1) Spindle phase synchronization (SPPHS: Y18B1)
(2) Phase shift calculation request (SSPHM: Y18B3)
(3) Phase offset request (SSPHF: Y18B4)
(4) Spindle synchronization: Phase error/Hob axis delay angle (R6516)
Cont.
Signal name
Spindle synchronization: Phase error
A
monitor
[Function]
The phase error during the spindle phase synchronous state can be monitored.
[Operation]
The phase error during the spindle phase synchronous control is output by the pulse unit.
Note
(1) Refer to the signal of the 1st spindle when the parameter "#1440 multi_sp_syn" (Multiple spindle synchronization
valid) is set to "0".
(2) Refer to the synchronized spindle's signal when the parameter "#1440 multi_sp_syn" (Multiple spindle synchroniza-
tion valid) is set to "1".
[Related signals]
(1) Spindle synchronization: Phase error monitor (lower limit) (R6520)
(2) Spindle synchronization: Phase error monitor (upper limit) (R6521)
IB-1501616-D
Abbrev.
1stSP
2ndSP
R6518
R6568
R6618
Abbrev.
1stSP
2ndSP
R6519
R6569
R6619
322
3rdSP
4thSP
5thSP
6thSP
R6668
R6718
R6768
3rdSP
4thSP
5thSP
6thSP
R6669
R6719
R6769
7thSP
8thSP
R6818
R6868
7thSP
8thSP
R6819
R6869

Advertisement

Table of Contents
loading

This manual is also suitable for:

M800v series

Table of Contents