Mitsubishi Electric M80V Series Manual page 263

Hide thumbs Also See for M80V Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Interface Manual
4 Explanation of Interface Signals
4.1 PLC Input Signals (Bit Type: X***)
Cont.
Signal name
A
Current detection
[Function]
This signal is output from the spindle controller (spindle drive) with high-speed serial coupling specifications, and informs
that the load current is about to reach the permissible maximum current. This signal is used to prevent the cutter from
biting into the workpiece, for example.
[Operation]
This signal (CDO) turns ON when the motor current is above the threshold (110% output) close to the permissible
maximum current (120%).
Note
(1) This signal is valid only for systems that are high-speed serially coupled to the spindle controller.
Cont.
Signal name
A
Speed detection
[Function]
This signal is output from the spindle controller (spindle drive) with high-speed serial coupling specifications and informs
that motor speed is dropped below the speed specified by parameter.
[Operation]
This signal (VRO) turns ON when the motor speed (motor rotation speed) falls below the detection level specified by the
spindle parameter "#13028 SP028 SDTS" (Speed detection set value).
Spindle motor speed
Spindle motor speed
Speed detection (VR0)
Speed detection (VR0)
Note
(1) This signal is valid only for systems that are high-speed serially coupled to the spindle controller.
[Related signals]
(1) Speed detection 2 (SD2: X189D)
Cont.
Signal name
A
In spindle alarm
[Function]
This signal is output from the spindle controller (spindle drive) with high-speed serial coupling specifications and informs
that some kind of alarm has occurred on the spindle controller.
[Operation]
This signal turns ON when an alarm is detected on the spindle controller side.
To cancel the alarm, reset (reset & rewind) the controller, turn OFF the controller, or turn OFF the spindle controller. The
reset method depends on the type of alarm.
Typical examples of alarm are listed below. For details of alarm contents and cancel procedure, refer to the "Instruction
Manual" of the spindle drive unit used.
 Overcurrent
 Breaker trip
 Motor overheat
Note
(1) This signal is valid only for systems that are high-speed serially coupled to the spindle controller.
IB-1501616-D
Abbrev.
1stSP
2ndSP
CDO
X1889
X18E9
X1949
Abbrev.
1stSP
2ndSP
VRO
X188A
X18EA
X194A
Speed command
Speed command threshold
(SP020)
(SP020)
Abbrev.
1stSP
2ndSP
FLO
X188B
X18EB
X194B
250
3rdSP
4thSP
5thSP
6thSP
X19A9
X1A09
X1A69
3rdSP
4thSP
5thSP
6thSP
X19AA
X1A0A
X1A6A
3rdSP
4thSP
5thSP
6thSP
X19AB
X1A0B
X1A6B
7thSP
8thSP
X1AC9
X1B29
7thSP
8thSP
X1ACA
X1B2A
7thSP
8thSP
X1ACB
X1B2B

Advertisement

Table of Contents
loading

This manual is also suitable for:

M800v series

Table of Contents