4 Explanation of Interface Signals
4.2 PLC Input Signals (Data Type: R***)
Cont.
Signal name
A
Presetter interlock
[Function]
The interlock direction in the CNC is output after the sensor is entered in the tool presetter.
[Operation]
The interlock direction to the entrance direction in the CNC is output after the sensor is entered during the tool
measurement mode (TLMS ON).
This signal is turned OFF when the escape operation completion conditions are satisfied.
This signal turns OFF when the tool measurement mode signal is turned OFF.
This signal is not output when the tool measurement mode is not entered.
F
E
D
C
1: In interlock
0: Interlock cancel or tool measurement mode OFF
[Related signals]
(1) Tool length measurement 2 (TLMS: YC21)
IB-1501616-D
Abbrev.
$1
R583
B
A
9
8
7
6
$2
$3
$4
R783
R983
R1183
5
4
3
2
1
0
In presetter interlock +1 axis
In presetter interlock +2 axis
In presetter interlock +3 axis
In presetter interlock +4 axis
In presetter interlock +5 axis
In presetter interlock +6 axis
In presetter interlock +7 axis
In presetter interlock +8 axis
In presetter interlock -1 axis
In presetter interlock -2 axis
In presetter interlock -3 axis
In presetter interlock -4 axis
In presetter interlock -5 axis
In presetter interlock -6 axis
In presetter interlock -7 axis
In presetter interlock -8 axis
302
$5
$6
$7
R1383
R1583
R1783
R1983
$8