4 Explanation of Interface Signals
4.4 PLC Output Signals (Data Type: R***)
Cont.
Signal name
Diagnosis data output: Select spindle for motor insulation
A
degradation detection
[Function]
This signal is used to select the spindle for insulation resistance measurement.
[Operation]
When the control starts measuring the motor insulation resistance, the measurement starts on the spindle for which the
signal is ON.
F E
D C
B A
9
[Related signals]
(1) Diagnosis data output: Motor insulation degradation detection request (IDDD: R20481)
Cont.
Signal name
A
Laser: Laser output override
[Function]
This signal is used to set the override value of the laser output (W).
[Operation]
This register can be set within the range of 0% to 100% in 1% increment.
When a value larger than 100% is set, the value is regarded as 100%.
[Related signals]
(1) Laser: Laser beam irradiation ON (Y1CA7)
Cont.
Signal name
A
Touchscreen operation disabled
[Function]
Touchscreen operation can be temporarily disabled by using this signal (TP_INVALD).
[Operation]
When you turn ON (disable) R20480 bit0, the touchscreen operation is disabled.
When you change R20480 bit0 from OFF (enable) to ON (disable) with the touchscreen pressed, the touch is interpreted
to be released at the time of ON.
When you change R20480 bit0 from ON (disable) to OFF (enable) with the touchscreen pressed, the touch is interpreted
to be made at the time of OFF.
IB-1501616-D
8
7 6
5
4
3
2
1
0
Abbrev.
Common ($)
SPIDDDAX
R20451
Degradation detection axis selection 1st spindle
Degradation detection axis selection 2nd spindle
:
Degradation detection axis selection 16th spindle
Abbrev.
Common ($)
R20453
Abbrev.
Common ($)
TP_INVALID