Mounting The Liner; Attaching The A7 Mig G Gun Neck; Attaching The A7 Mig W Gun Neck - Kemppi Robot Gun Mount T1 Operating Manual

Table of Contents

Advertisement

11.5 Mounting the liner

New liners have to be shortened to the actual length of the cable assembly.
• For handling the liners, please observe the enclosed wire guide liner mounting
instructions.
• Strip 350 mm of the insulation sheathing of the liner from the front end after
determining the correct length.

11.6 Attaching the A7 MIG G gun neck

This section describes how to attach the A7 MIG G gun neck.
Figure 10: Attaching the A7 MIG G gun neck
1.
A7 MIG G gun neck
2.
Hexagon wrench
3.
Gun mount T1 G
4.
Set screws (2 pcs.)
Proceed as follows:
1.
Equip the A7 MIG G gun neck (1) with a tip adapter, contact tip, and gas nozzle.
2.
Insert the A7 MIG G gun neck (1), via the guide grooves, into the robot mount (3) as
far as it will go.
3.
Tighten the set screws (4) with a hexagon wrench (2). Tightening torque
M = 2.5 Nm.
15
© Kemppi Oy 2016

11.7 Attaching the A7 MIG W gun neck

This section describes how to attach the A7 MIG W gun neck.
Figure 11: Attaching the A7 MIG W gun neck
1.
A7 MIG W gun neck
2.
Positioning pin
3.
Robot mount T1
4.
Retaining nut
Proceed as follows:
1.
Equip the A7 MIG W gun neck (1) with a tip adapter, contact tip, and gas nozzle.
2.
Introduce the positioning pin (2) into the marked bore. The A7 MIG W gun neck (1)
can only be fastened in this position.
3.
Screw down the A7 MIG W gun neck (1) with the retaining nut (4) on the robot
mount (3).
After the gun has been used for several days, it may no longer be possible to
disconnect it by hand. To disconnect the gun, use a suitable wrench. Do not use pliers to
disconnect the gun.