3-68 Hardware installation

T1 Connection

Figure 3-17
Connecting the NAC to a Meridian MAX node—T1 Connection
Î Î Î Î Î Î Î
Î Î Î Î Î Î Î
Î Î Î Î Î Î Î
Î Î Î Î Î Î Î
Î Î Î Î Î Î Î
Î Î Î Î Î Î Î
Î Î Î Î Î Î Î
Î Î Î Î Î Î Î
Î Î Î Î Î Î Î
Î Î Î Î Î Î Î
NAC 2
Î Î Î Î Î Î Î
Î Î Î Î Î Î Î
Î Î Î Î Î Î Î
Î Î Î Î Î Î Î
Î Î Î Î Î Î Î
Î Î Î Î Î Î Î
Î Î Î Î Î Î Î
Î Î Î Î Î Î Î
553-4011-110 Standard 1.0 November 1994
The NAC 2 system can be connected to a Meridian MAX node through
digital lines such as T1. During the system's installation, the network link
port on the NAC and the Meridian MAX must be configured as direct
connection ports. In the NAC system, the network link baud rate should be
set to 9600 through the Network Definition screen. The T1 network delay
must be less than 0.5 second.
Figure 3-17 shows a NAC 2 connected to a Meridian MAX via a T1
connection. Use either an NT7D58Ax or an NT7D99Ax cable to connect
the T1 network to the Meridian MAX and NAC octopus cables.
NT7D58Ax cable
NT7D99Ax cable
Octopus cable